1.Rating : TEMP 80 ℃ : VOLTAGE 30V DC
2. Conductor Resistance: AT 20 ℃ MAX
28AWG: 237.25 W /km; 24AWG: 93.25 W /km
3. Insulation Resistance: 10M W -km min at 20 ℃ dc 500V.(EIA-364-21)
4. Dielectric Strength : AC 500V/1minute no breakdown. (EIA-364-20)
5. Coaxial cable Impedance: 75 ± 5 W |
1.Tensile Strength: Unaged: 1500PSI min Aged: 70% min
2. Elongation: Unaged: 100% min Aged: 65%
3. Heat shock test: NO CRACKING
4. Cold bend test: NO CRACKING
5. Deformation test: MIN 50%
6. Flame test: PASSED UL VW-1 |